Oil-filled Distribution Transformer also named oil immersed transformer, distribution transformer,voltage electrical power transformer etc.

What is Oil-filled Distribution Transformer?

Oil-filled Distribution Transformer is one of the important equipment in power supply & distribution system of industrial and mining enterprises and civil buildings. It reduces the network voltage of 10 (6) or 35 kV to 230/400 V bus voltage used by users. This kind of product is suitable for AC 50 (60) Hz, three-phase maximum rated capacity 2500 KA (single-phase maximum rated capacity 833 KA, generally not recommended to use single-phase transformer), can be used indoors (outside), capacity 315 KA and below can be installed on the pole, the ambient temperature is not higher than 40 ℃, not lower than – 25 ℃, the highest daily average temperature is 30 ℃, the highest annual average temperature is 20 ℃, relative humidity. No more than 90% (ambient temperature 25℃) and no more than 1000 m above sea level. If it does not conform to the above-mentioned conditions of use, appropriate quota adjustments shall be made in accordance with the relevant provisions of GB6450-86.

Oil-filled Distribution Transformer History

Transformer oil is a kind of petroleum liquid, which has the possibility of combustion and environmental protection shortcomings. However, due to the excellent performance and low cost of transformer oil, most power transformers still use transformer oil as insulation and cooling medium.


At the end of the 19th century, transformer oil began to be used as insulation and cooling medium. Oil-immersed Distribution transformer appeared. Besides abundant natural storage and low price, transformer oil has been widely used because of its following characteristics.
  1. With the use of fiber materials, the insulation performance is good, the insulation distance can be reduced and the cost can be reduced.
  2. Transformer oil has low viscosity and good heat transfer performance.
  3. The core and winding can be well protected from the influence of moisture in the air.
  4. Protect insulating paper and board from the effect of oxygen, reduce the aging of insulating material and prolong the life of transformer.
At present, most large and medium-sized transformers still use transformer oil as cooling and insulation medium, except for some special purpose medium and small capacity transformers and gas transformers. The insulation of transformer impregnated with transformer oil is grade A, and the long-term working temperature is 105 ℃.

Oil-filled Distribution Transformer Corrugated Fins Cooler Wall Manufacturing Related Machines:

Automatic Corrugated Fins Wall Manufacturing Line



Corrugated Fins Wall Forming Machine




Full-auto PLC Corrugated Fins Seam Welding Machine



Hydraulic Decoiler




Want to know more?(Marketing Title)

Phone: 008615195010186
Email: cnkylt@aliyun.com

评论

此博客中的热门博文

CNC MACHINE BE CLASSIFIED BY SERVO CONTROL MODE

Servo control mode to classify CNC machine tool. (1) open loop control CNC machine tool The feed servo drive of this kind of machine tool is open-loop, that is, there is no detection feedback device. Generally, its driving motor is a stepping motor. The main feature of stepping motor is that every time the control circuit changes the command pulse signal, the motor will rotate a step angle, and the motor itself has self-locking ability. The drive circuit is controlled by the pulse distributor, which controls the coordinate displacement by changing the number of pulses, the displacement speed by changing the frequency of pulses, and the direction of displacement by changing the distribution sequence of pulses. Therefore, this control mode is characterized by convenient control, simple structure and low price. The command signal flow from the CNC system is unidirectional, so there is no stability problem of the control system, but because the error of the mechanical transmission...

Tapping failure reasons analysis

After the first metal part be tapped, we always to check it: if pass the thread gauge inspection? The inspection result is OK, we can do mass production. If it fails, We should consider which reasons cause tapping faiulre. KYLT provide Metal Machining services for:  WEDM, EDM, DRILL, TAPPING ,  CNC LATHING ,  CNC MILLING ,  ALUMINUM / MAGNESIUM / PLASTIC RAPID PROTOTYPES MAKING . 1PCS ORDER IS ALLOWED. Aluminum CNC machined workpiece Normally, the following reasons may cause screw thread faiulre: 1) UNQUALIFIED TAP Tap is wear or bad 2) QUALIFIED DRILLING HOLE (BEFORE TAPPING) If the hole is too small, because of friction, will increase the difficulty of tapping, while tapping faster wear, and vice versa, the hole is too big, it can easily tap into, but the quality of teeth is very poor, because the diameter of teeth will become larger, relative to the screw nut bonding force is insufficient, easy to slide teeth. In M3 *0.5, the correct hole (general...

SELECTION PRINCIPLE OF CUTTING PARAMETERS FOR SCREW THREAD TURNING

Because the pitch (or lead) of the thread is specified by the drawing, the key to choose the cutting parameters when  turning  the screw thread is to determine the spindle speed n and the cutting depth AP. 1) SELECTION OF SPINDLE SPEED TO DO SCREW THREAD TURNING According to the mechanism that the spindle turns 1 and the cutter feeds 1 lead when turning the thread, the feed speed of the CNC lathe is determined by the selected spindle speed. The thread lead (which is the pitch when the thread is single head thread) instructed in the thread processing program section is equivalent to the feed speed VF VF = n f (1) expressed by the feed rate f (mm / R) From Formula 1, it can be seen that the feed speed VF is proportional to the feed amount F. if the spindle speed of the machine tool is selected too high, the converted feed speed will greatly exceed the rated feed speed of the machine tool. Therefore, when selecting the rotation speed of the main shaft for turning the threa...